Switch Hardware Requirements

ONIE has modest hardware requirements. The NOS definitely has additional hardware requirements.

Note

ONIE has no specific CPU architecture requirements -- it is Linux.

Currently ONIE supports x86 and PowerPC CPU architectures.

This section lists the switch hardware requirements for an ONIE-compatible switching platform.

For CPU architecture specific details see these sections:

Board EEPROM Information Format

Each ONIE system must include an EEPROM which contains various system parameters assigned by the manufacturer. This EEPROM includes information such as the MAC address(es) allocated to the system, the serial number, the date of manufacturer, etc. The name of the EEPROM format specified here is TlvInfo, because the information contained in the EEPROM is found in TLVs, or Type Length and Value fields.

Definition of the TlvInfo EEPROM Format

The first eight bytes in the EEPROM are the NULL-terminated ASCII string TlvInfo. This identification string can be used as a simple, preliminary check that the EEPROM conforms to the TlvInfo format defined here. Additional validation checks should be performed to validate that the TlvInfo format is really being used, such as validating the CRC. But this string provides a good clue, when debugging or dumping memory, that what follows is in the TlvInfo EEPROM format.

The identification string is followed by a single-byte version value. This value is set to 0x01 for the TlvInfo EEPROM format described on this page. Since the format described herein is very flexible and extensible, this value is not expected to ever change, but is included just in case. Software should not assume anything about the format of the data that follows this byte if it has not been written to support the version it reads from this value. The values 0x00 and 0xFF are reserved and will never be used.

The version field is followed by two bytes, which give the total length of the data that follows. This field is in big endian order and includes the cumulative length of all of the TLV fields that follow. This field can be used to determine the amount of data to read, if the EEPROM data is read in bulk, following the first 11 bytes. This field can also be used to determine the location of the CRC, since the CRC-32 TLV is fixed length and always the last TLV in the EERPOM.

The total length field is followed by the EEPROM system data, known as TLV fields. Each TLV field is composed of three sub-fields: a type code field, a length field, and a value field, in that order.

  • Type code: This is a single byte that defines the type and format of the value field. These types are defined in the table below. Since these type codes can be added over time, software that does not understand a particular type code should treat the value field as opaque data, not assigning any meaning to its type or format. Type codes 0x00 and 0xFF are reserved and will never be used. This allows for up to 254 type codes.
  • Length: This is a single byte that contains the number of bytes in the value field. Valid values of this field range from 0 to 255. A length of zero means that there is no value field associated with this type code. In that case, the byte following the length field is the first byte of the next TLV, its type code field.
  • Value: This field contains the value for the specified type code. It may range in size from 0 to 255 bytes. The format of this field is defined, below, for each of the individual type codes. Because each TLV contains a length field, ASCII strings are not NULL-terminated, unless otherwise specified as described below.

Only the CRC-32 TLV is required to be present by this specification, but some systems may not initialize properly without the presence of other fields. The CRC-32 TLV must occur last. This field can be quickly found at the following offset in the EEPROM by adding 11 (the length of the fixed header information) + the value of the total length field - 6 (the length of the CRC-32 TLV field).

The total length of the TlvInfo EEPROM data, from the first byte of the identification string to the last byte of the CRC TLV, must be less than or equal to 2048 bytes.

The layout of the entire EEPROM block looks like:

Field Name Size in Bytes Value
ID String 8 "TlvInfo"
Header Version 1 0x01
Total Length 2 Total number of bytes that follow
TLV 1 Varies The data for TLV 1
TLV 2 Varies The data for TLV 2
..... ..... .....
TLV N Varies The data for TLV N
CRC-32 TLV 6 Type = 0xFE, Length = 4, Value = 4 byte CRC-32

Type Code Values

The following type codes are defined.

Type Code Length Description Format
0x00 None Reserved This type code is illegal and will never be used, so that it will be easy to detect if a portion of the EEPROM is erased.
0x21 Variable Product Name An ASCII string containing the product name.
0x22 Variable Part Number An ASCII string containing the vendor's part number for the device.
0x23 Variable Serial Number An ASCII string containing the serial number of the device
0x24 6 bytes MAC #1 Base Six bytes containing the base MAC address for this device. The first three bytes contain the OUI of the assigning authority.
0x25 19 bytes Manufacture Date An ASCII string that specifies when the device was manufactured. The format of this string is: MM/DD/YYYY HH:NN:SS where MM is the month (01-12), DD is the day of the month (01-31), YYYY is the year, HH is the hour (00-23), NN is the minute (00-59), and SS is the second (00-59).
0x26 1 byte Device Version A single byte indicating the version, or revision, of the device.
0x27 Variable Label Revision An ASCII string containing the label revision.
0x28 Variable Platform Name An ASCII string which identifies a CPU subsystem (CPU, architecture, DRAM, NOR flash). Very useful when the CPU resides on a daughter card. Typically this includes <arch>-<machine>-<machine_revision>.
0x29 Variable ONIE Version An ASCII string containing the version of the ONIE software installed by the manufacturer.
0x2A 2 bytes Num MACs A two-byte big-endian unsigned integer describing the number of sequential MAC addresses allocated to this device, starting with the value specified in the MAC #1 Base TLV (code 0x2A). Valid values for this field range from 1 to 65535.
0x2B Variable Manufacturer An ASCII string containing the name of the entity that manufactured the device.
0x2C 2 bytes Country Code A two-byte ASCII string containing the ISO 3166-1 alpha-2 code of the country where the device was manufactured.
0x2D Variable Vendor The name of the vendor who contracted with the manufacturer for the production of this device. This is typically the company name on the outside of the device.
0x2E Variable Diag Version An ASCII string containing the version of the diagnostic software.
0x2F Variable Service Tag An ASCII string containing a vendor defined service tag.
0xFD Variable Vendor Extension This type code allows vendors to include extra information that is specific to the vendor and cannot be specified using the other type codes. The format of this value field is a four byte IANA enterprise number, followed by a vendor defined string of bytes. The format of the string of bytes is entirely up to the vendor, except that it can be, at most, 255 bytes long, including the IANA enterprise number. If more space is needed, then multiple TLVs with this type code can be used.
0xFE 4 bytes CRC-32 A four-byte CRC which covers the EEPROM contents from the first byte of the EEPROM (the "T" in the "TlvInfo" identification string) to the length field of this TLV, inclusive. This CRC uses the crc32 algorithm (see Python's binascii.crc32() function).
0xFF None Reserved This type code is illegal and will never be used, so that it will be easy to detect if a portion of the EEPROM is erased.

Note about MAC Addresses

A very critical characteristic of a switching platform EEPROM is the number of MAC addresses allocated to the machine. The ONIE project requires allocating 1 MAC address for every serdes on the box.

For example, consider a machine that has one Ethernet management port and a switching ASIC with 48x10G ports plus 6x40G ports. Each 40G port could be broken out into 4x10G ports. Therefore, the total number of MAC addresses this machines requires is:

1  -- Ethernet management port
48 -- 1 for each 48x10G port
24 -- 4 for each 6x40G port
-----------------------------
73 Total MACs

To encode that in the EEPROM, set TLV code 0x2A (Num MACs) to 73.

Maintenance of this EEPROM format specification and allocation of the TLV type codes is handled by the ONIE Project.

Hardware Face Plate and FRU Numbering

The ONIE project requires the following conventions for the sheet metal silkscreen on the machine:

  1. Switch ports are labeled starting with the number "1".
  2. Switch ports are labeled top to bottom, left to right. For example, consider a 48 port switch with two rows of switch ports (two rows of 24 ports). The ports along the top row are labeled "1, 3, 5 ... 47" and the bottom row is labeled "2, 4, 8 ... 48".
  3. Field Replaceable Units (FRUs) are labeled starting with the number "1". This typically applies to field pluggable power supplies and fan modules. For example, a system with 2 PSUs and 3 fan modules would label the PSUs "1, 2" and the fans "1, 2, 3".

Hardware Documentation

The ONIE project requires that the switch packaging include a one page (two sides printed) Quick Start Guide flyer. This is similar to what is included with most commercial products.

Such a flyer would include the following:

  • ONIE version number and certification number/date
  • Stencil of front & rear switch view with call outs or arrows to eth0 "management Ethernet" and "out of band" serial console.
  • A geographic layout of the temperature sensors, i.e. where are the temperature sensors located on the board.
  • Console port pin out, baud rate / settings information (115200 baud default).
  • Generic ONIE installation instructions (visual of network waterfall, file name discovery) -- pointers to ONIE website or similar tiny URL with more verbose instructions.
  • Generic ONIE debugging (ssh/telnet access, syslog) -- pointers to ONIE website or similar tiny URL with more verbose instructions.

Following these requirements will improve the operational experience of the end customer.

Asset Tracking and Labeling

The ONIE project requires the following regarding asset tracking labels:

  • Human and machine readable barcodes that represent the eth0 base MAC address, serial number, product identification and CPU ID.
  • For racked environments these labels should be place on the sides of the switch, not on the top or bottom of the switch.
  • On platforms that support dmidecode, the stickers should encode the data in the same format as the SMBIOS/DMI standard.

Following these requirements will improve the operational experience of the end customer.

<< Previous: Overview | Next: Linux Kernel >>