IACQ - Secure ECG Acquisition Library

Overview

The IACQ library provides a robust Python interface for communicating with an FPGA hardware accelerator. It implements the UART command protocol required to send ECG waveforms and perform ASCON-128 authenticated encryption. The library strictly follows the Fail-Fast principle, validating all cryptographic inputs before transmission.

Installation

Ensure you have Python 3.10+ installed. It is recommended to use a virtual environment.

  1. Clone this repository.
  2. Install the required dependencies:
pip install -r requirements.txt

Quick Start

Here is a minimal example to establish a connection and set an encryption key:

from iacq import IACQ
from exceptions import FPGAError

# Use a context manager for safe resource handling
try:
    with IACQ(port='COM8', emulator=False) as fpga:
        # Define a 16-byte key
        key = bytes.fromhex("8A55114D1CB6A9A2BE263D4D7AECAAFF")

        # Send key to the FPGA
        fpga.send_key(key)
        print("Hardware ready for encryption!")

except FPGAError as e:
    print(f"FPGA Operation Failed: {e}")

Running the Application

The Quick Start section above shows how to use the library programmatically. To run the full application with the real-time ECG dashboard, simply execute:

python visualization.py

Hardware vs. Emulator Usage

This library supports both physical hardware and a software emulator for development without the FPGA board.

  • Hardware Mode: Set emulator=False and provide the correct serial port (e.g., 'COM8' on Windows or '/dev/ttyUSB0' on Linux). This uses pyserial to communicate with the physical board.

  • Emulator Mode: Set emulator=True (the port parameter is ignored). This routes all communication through the FPGAEmulator class, simulating hardware delays and ASCON cryptography locally.

⚠️ Why code that works in the emulator may fail on hardware: The emulator runs entirely in software, so it has no timing constraints or memory limits. The physical FPGA board introduces real propagation delays between commands and operates with limited internal buffers. If commands are sent too fast or data exceeds buffer capacity, the board may drop bytes or return unexpected responses. Always add appropriate delays between UART commands when running on hardware and verify your baud rate is set to 115200.

Troubleshooting

Problem Cause Solution
ConnectionRefusedError Port is already in use by another program (e.g., Vivado or another terminal). Close the other application holding the COM port and retry.
FPGATimeoutError Incorrect baud rate or disconnected board. Verify the board is plugged in and the baud rate is set to 115200.
FPGAValidationError Incorrect data type or length. Ensure keys and nonces are exactly 16 bytes and passed as bytes objects, not strings.
No Logs Output Emulators overriding the logging configuration. Ensure logger.propagate = False is set in your main script configuration.

Encryption Protocol

Command Sequence

The FPGA communication follows a strict 7-step command sequence:

  1. K — Load encryption key (16 bytes)
  2. N — Set nonce (16 bytes)
  3. A — Set associated data (padded to 10 bytes)
  4. W — Send waveform data (padded to 184 bytes)
  5. G — Start encryption
  6. T — Retrieve authentication tag (16 bytes)
  7. C — Retrieve ciphertext (181 bytes extracted from 184 bytes)

Flow Diagram

[Plaintext Waveform 181B] + [Padding 3B]
           |
           v
+-------------------------+
| FPGA Hardware (ASCON)   | <--- Key (16B), Nonce (16B), AD
+-------------------------+
           |
           v
[Ciphertext 181B] + [Tag 16B]

Performance Benchmarking

To verify the system's readiness for real-time medical monitoring, a stress test was conducted using the full encryption/decryption pipeline.

Test Configuration

  • Dataset: 5,000 ECG waveforms (181 bytes each)
  • Mode: FPGA Emulator (simulated UART @ 115200 baud)
  • Operations per cycle: 7 UART commands (K, N, A, W, G, T, C) + Python-side ASCON decryption

Results

Metric Value
Total Processed 5,000 waveforms
Success Rate 100% (0 errors)
Avg. Latency per Cycle 125.44 ms
System Throughput 7.97 waveforms/sec

Analysis: With a throughput of nearly 8 waveforms per second, the system is ~8x faster than a standard human heart rate (60 BPM / 1 Hz). This provides a significant safety margin for real-time processing, even during high-stress physiological conditions (tachycardia) or multi-sensor environments.


Security Analysis: The Danger of Nonce Reuse

This project includes a formal security test suite (tests/test_security.py) to validate ASCON-128 AEAD properties. Beyond standard Bit-Flip and Wrong-Key tests, we implemented a specific test demonstrating Nonce Reuse vulnerabilities.

Unlike standard stream ciphers where nonce reuse leaks the XOR of the entire plaintext, ASCON utilizes a Sponge Construction. Our tests successfully prove that:

  1. Reusing a nonce perfectly leaks the XOR of the plaintexts only for the first block (the 8-byte rate of ASCON-128).
  2. After the first difference, the internal sponge state diverges, protecting the rest of the message.

This demonstrates both the vulnerability of poor nonce management and the resilience of the sponge architecture.


Hardware Authenticity (Bitstream Verification)

To verify that the hardware implementation was compiled locally rather than using pre-compiled binaries, SHA-256 hashes were computed for the generated bitstreams. Vivado embeds unique build timestamps, ensuring unique binaries even for identical source code.

File SHA-256 Hash
inter_spartan.bit (Provided) 32A3810828796B11F369C86B1876A3DEF37AEAFB29CC6C2835153BA1B8F0A3FD
ECG.bit (Custom Build) 199AF6DE57FE0944A77803C650EF321CBA33B535B2859A36E3174A79230E2057

Hashes mismatch confirms the authenticity of the local Vivado synthesis and implementation.


Advanced Features

1. Advanced GUI Application

The standard visualization was transformed into a full Qt5 Graphical User Interface (visualization.py). This professional dashboard features:

  • Separated Layouts: ECG Plot (75% screen) separate from Medical Metrics (25%).
  • Hardware Acceleration: Using pyqtgraph to maintain high frame rates even with real-time decryption.
  • Interactive Controls: A user-controllable Pause/Resume button that directly controls the encryption/decryption loop and the neuro-signal processing threads.

2. Arrhythmia Screening (NeuroKit2 Integration)

Instead of just displaying raw heart rate, the dashboard integrates a real-time medical analysis engine:

  • Dynamic Thresholding: Automatically detects and flags Tachycardia (>100 BPM), Bradycardia (<60 BPM), or Irregular Rhythms (via HRV/QRS duration) with color-coded visual alerts.
  • Advanced HRV: Calculation of pNN50 and RMSSD metrics to assess autonomic nervous system balance.
  • PQRST Delineation: Calculation of precise QRS Duration for more detailed cardiac analysis. -e

Author

Developed by Ronald Marín Cardona.

About

Python library for secure ECG signal acquisition and ASCON-128 authenticated encryption via FPGA hardware acceleration