BESS Domain Knowledge

This document contains the domain knowledge an analyst needs to answer questions about the BESS Manager battery optimization system. It is the single source of truth for both the in-app AI chat and the GitHub analysis agent.

For deeper investigation, use tools to read the source code directly. Key files: core/bess/dp_battery_algorithm.py (optimizer), core/bess/models.py (data models), core/bess/energy_flow_calculator.py (flow decomposition), core/bess/growatt_schedule.py (schedule generation), core/bess/battery_system_manager.py (orchestrator).

How the System Works

BESS Manager optimizes a home battery to minimize electricity costs. Every 15 minutes it re-runs a dynamic programming optimizer that looks at:

  • Electricity prices (today + tomorrow when available, at 15-min resolution)
  • Solar production forecast
  • Consumption prediction (time-of-day shaped or flat, depending on strategy)
  • Current battery state (charge level, cost basis of stored energy)
  • Battery parameters (capacity, efficiency, cycle cost)

The optimizer produces a schedule of battery actions (charge / discharge / idle) for each 15-minute slot from now through the end of available price data. This schedule is applied to the inverter via Home Assistant.

Re-optimization: The system re-runs every 15 minutes. Each run uses the latest actual data (replacing predictions with measurements) and may produce a different schedule. Common triggers for schedule changes:

  • Tomorrow's prices become available (typically around 13:00 for Nordpool)
  • Actual solar or consumption differs from the forecast
  • Battery state differs from what was predicted

The Dynamic Programming Algorithm

The optimizer uses backward induction. Starting from the last period and working backwards, it evaluates all possible battery actions at each period and selects the one that minimizes total electricity cost over the remaining horizon.

State space: Discretized battery state of energy (SOE) levels.

Actions: Charge, discharge, or idle at various power levels — filtered by physical constraints (available energy, remaining capacity, power limits).

Transition: Each action updates SOE accounting for charge/discharge efficiency losses and updates the cost basis of stored energy.

Objective: Minimize net electricity cost (grid import cost minus export revenue) while accounting for battery cycle degradation costs and a terminal value for energy remaining at end of horizon.

Terminal value: Applies unconditionally at whatever the current horizon boundary is — midnight-today when only today's prices are available, midnight-tomorrow once tomorrow's prices have landed and the horizon extends. Without it, the DP has no visibility past the horizon and would have no reason not to drain the battery completely in the last period; this holds regardless of where that boundary currently sits, since no provider ever supplies data past midnight-tomorrow either. Each leftover kWh at the horizon's end is valued at:

terminal_value = median(buy_prices) * efficiency_discharge - cycle_cost

where buy_prices is the median over the full remaining horizon, capped at max(sell_prices) * efficiency_discharge - cycle_cost — an arbitrage-consistency cap that prevents the estimate from exceeding what could actually be realized by selling at the best available price (core/bess/battery_system_manager.py:1841-1921, _calculate_terminal_value; see issues #126/#244/#246/#345). This is the mechanism to check first for "why didn't the battery discharge everything right before midnight" or "why does it hold charge near the end of the horizon" — it applies at both the today-only and today+tomorrow boundary, so this remains the first thing to check even after tomorrow's prices have arrived (until #345, it was incorrectly zeroed in that case; see the #345/#126 threads for the "tonight's export moves a day later" symptom this was suspected of, and ultimately ruled out for a specific bundle).

Unlike buy_prices, the sell_prices fed into the cap are not the full remaining-horizon window — the caller (_run_optimization, battery_system_manager.py:~2050-2075) scopes them to periods on the terminal boundary's own calendar day only (issue #422). On a 48h-extended horizon, using the full window let an already-committed near-term peak (e.g. today's still-upcoming best sell slot) inflate the cap for tomorrow's terminal boundary, making the DP hold charge through all of tomorrow's own (lower but still profitable) export opportunities instead of exporting into them — this was the actual mechanism behind the long-reported #126 "tonight exports, tomorrow evening doesn't" symptom. buy_prices is unaffected by this scoping — a median is already resistant to a single-period outlier, so only the cap's max() needed the day boundary.

The cap is skipped entirely on a fixed/flat export tariff (max(sell_prices) == min(sell_prices), e.g. UK Octopus Outgoing Fixed) — there, every period shares the same sell price, so max(sell_prices) is not a real future opportunity being forgone, and applying the cap anyway forces terminal value below the round-trip breakeven for any buy price, making it arithmetically impossible to store surplus solar for post-horizon use (issue #359). On any market with genuine price variation (Nordic, Belpex, UK variable-export), this carve-out is inert and the cap applies exactly as described above.

Self-throttling near self-consumption (issue #240): In _compute_reward, a discharge whose overshoot above home_consumption is <= BATTERY_EXPORT_THRESHOLD_KWH (0.01 kWh, core/bess/dp_battery_algorithm.py:96) has its grid_exported forced to zero for reward purposes — the DP treats it as pure self-consumption, not an export sale, because load-first hardware doesn't reliably deliver a trivial overshoot to the grid in practice. When evaluating whether a small discharge was "worth" sell_price, check this threshold first: below it, the relevant alternative-value comparison is against the buy price avoided, not the sell price (core/bess/dp_battery_algorithm.py:511-522).

Cost basis tracking (weighted average): When the battery charges at different prices over time, the system tracks the cost of stored energy as a weighted average, not FIFO. On charge: new_cost_basis = (soe * cost_basis + new_energy_cost) / next_soe (core/bess/dp_battery_algorithm.py:496-498). On discharge, cost_basis is left unchanged — there is no "oldest energy first" queue or layered accounting anywhere in the code.

All-IDLE safety net (not a profit threshold): After optimization, an all-IDLE schedule is unconditionally computed and swapped in only if its battery_solar_cost is cheaper than the optimized schedule's (core/bess/dp_battery_algorithm.py:1514-1536). This is a plain cost comparison — there is no minimum-profit threshold and no day-fraction scaling. An earlier design had a threshold/guardrail here; it was removed in the "Bellman-optimality guardrail removal" refactor (commit ee24537f/f57d4fed, docs/superpowers/specs/2026-07-06-dp-bellman-guardrail-removal-design.md) because the DP's backward induction already finds the Bellman-optimal schedule, making an extra economic gate redundant. What remains is a numerical safety net for SOE-discretization residual, not an economic judgment call. The fallback still passively absorbs any solar surplus into available battery room and pays wear cost on it, but never discharges to recoup that cost, so it isn't automatically better than what it would replace.

Shadow price (marginal value of stored energy): The backward induction builds a value-to-go for every (period, SOE-level) state — the best achievable result from that point onward. The shadow price of a period is the slope of that value across SOE: how much one extra kWh of stored energy is worth, in SEK, given the optimal future use of it. It is not the cost basis (what the energy cost to store — a sunk cost). It is the forward-looking opportunity value, and it automatically accounts for everything the optimizer can do with that kWh later: avoid a future expensive grid purchase, export it at a future high sell price, or — crucially — nothing extra, because upcoming solar will refill the battery anyway (replenishment). Each period's shadow price is stored on its decision data and is used at apply time for the SOLAR_EXPORT discharge gate (below).

The Governing Economic Law (read this first)

Every battery action is judged by its marginal net value against the next-best alternative for that same slot — never by its gross value, and never against "do nothing = 0".

The opportunity cost of a stored kWh is its forward-looking shadow_price (the DP's value-to-go slope), floored by sell_price when upcoming solar will replenish the battery for free. It is not the sunk cost_basis, and not zero.

Operational forms of the one law:

  • Discharge to grid is worthwhile only if sell_price × efficiency_discharge > opportunity_cost_of_stored_kWh.
  • Discharge to cover home load is worthwhile only if it beats the cheapest alternative for that kWh (usually a future avoided import at a higher buy price).
  • Charge is worthwhile only if the stored kWh's future value exceeds what it cost to store it (grid/solar cost + wear).

The classic error this prevents: treating sell_price > wear_cost as "profitable". That compares gross sale value to wear and ignores the counterfactual. If the real alternative is "let solar keep charging one more slot and export one slot earlier", the value captured is only the differential in sell price between the two slots, which must still clear the wear cost. A 6 öre differential against a 40 öre wear cost is a loss, not a 6 öre gain.

Reconciliation with the code: _compute_reward (core/bess/dp_battery_algorithm.py:409-541) no longer implements an explicit profitability floor. That anti-cycling floor was removed in the "Bellman-optimality guardrail removal" refactor (commit ee24537f/f57d4fed, docs/superpowers/specs/2026-07-06-dp-bellman-guardrail-removal-design.md); the function's current docstring states "No profitability veto: every physically valid discharge gets a finite reward... a separate floor on top of that is redundant at best." The governing economic law above still holds as the outcome of backward induction (the DP won't choose a discharge that isn't marginally worthwhile), but it is enforced by the value-to-go comparison across the whole horizon, not by a floor inside _compute_reward.

Facts vs Economics — where each lives in a debug bundle

Answer "what happened" and "why" from different parts of the bundle, in that order:

  • Facts (what happened): ## Optimization Schedules → ### Period Decisions table. Columns: Intent | Observed | BattAct | SOE start→end | BuyPrice | Savings. A negative BattAct with a falling SOE is a battery discharge — read this before proposing any mechanism. Solar-only export shows BattAct ≈ 0.
  • Economics (why): the Full Schedule JSON <details> block — sell_price, buy_price, cost_basis, shadow_price per period — plus ### Economic Summary.
  • Period ↔ clock time: slots are 15 minutes. Map the question's clock time to a period number and confirm it. Watch the off-by-one: the price shown for 15:45 is the 15:45 slot's price, not 16:00's.

Illustrative: applying the law (method demo, not a lookup)

Illustrative only — the method generalizes to any period. Do not pattern-match the scenario; reproduce the reasoning steps.

A battery discharges a small amount to grid in a slot where sell = 0.46, wear = 0.40.

  • Wrong (gross): 0.46 > 0.40 → +6 öre, profitable.
  • Right (marginal): the alternative is to let solar charge one more slot and export one slot earlier, so only the sell-price differential (~0.06) is gained, against 0.40 wear ⇒ ≈ −0.34 SEK/kWh, a loss. Equivalently: shadow_price (e.g. 0.876) and cost_basis (e.g. 0.62) both exceed sell 0.46, so the stored kWh is worth more kept than exported ⇒ do not discharge.
  • If different optimization runs disagree on such a near-threshold slot, the cause is shadow_price sensitivity across re-optimizations, not a missing mechanism.

Strategic Intents

Every 15-minute slot gets a strategic intent based on the energy flows the optimizer chose: GRID_CHARGING, SOLAR_STORAGE, LOAD_SUPPORT, BATTERY_EXPORT, SOLAR_EXPORT, IDLE. The exact classification thresholds live in core/bess/decision_intelligence.py — read that file directly rather than relying on a copy of the numbers here, since they are implementation detail that can change independently of this doc.

Hardware mapping: Intents control actual inverter behavior (register- based platforms — Growatt TOU/cloud/SPH; VPP-style platforms select grid_first/load_first per-period instead of via a persistent mode, see the SOLAR_EXPORT hardware-mapping note below):

  • GRID_CHARGING → battery_first mode + grid charge ON
  • LOAD_SUPPORT → load_first mode
  • BATTERY_EXPORT → grid_first mode (battery discharge to grid)
  • SOLAR_STORAGE / SOLAR_EXPORT / IDLE → load_first mode (solar serves home first)

BATTERY_EXPORT vs SOLAR_EXPORT (why the split exists)

Both export to grid, but they are different situations and need different inverter modes:

  • BATTERY_EXPORT: the battery is actively discharging to grid for profit → grid_first + an action-derived discharge rate.
  • SOLAR_EXPORT: the battery is idle and full; only the solar surplus flows to grid → load_first. The battery is not pushed to grid.

Earlier both were one intent (EXPORT_ARBITRAGE) mapped to grid_first, which wrongly locked the inverter in grid-export mode for hours during sunny daytimes while the battery sat unable to help the house.

The SOLAR_EXPORT discharge gate (load_first + discharge rate 0 or 100)

discharge_rate is a hardware register written every period, not just a schedule label. At discharge_rate=0 the battery is forbidden to discharge at all — so it cannot cover the house load if solar dips within a period. At discharge_rate=100 load_first lets the battery cover an intra-period deficit (it still won't export — that's grid_first).

Whether a SOLAR_EXPORT period should allow that cover is an economic choice, decided per period from the shadow price (above):

Cover the dip from the battery only when the stored energy is worth less than buying that energy from the grid right now: buy_price × discharge_efficiency ≥ shadow_price → rate 100, else rate 0`. (The efficiency factor applies only to the buy side — the shadow price is already per-kWh-of-stored-energy.)

What this works out to in practice — important for analysis:

  • During SOLAR_EXPORT the battery is full and exporting surplus, so its marginal kWh is only worth the export (sell) price — the surplus refills it for free (replenishment). The shadow price therefore ≈ the sell price.
  • Normal prices (buy > sell): the gate is 100 — covering the dip from the battery beats buying from grid, because solar refills the battery. This is the usual case.
  • Inverted prices (export premium or negative buy, i.e. sell ≥ buy×eff): the gate is 0 — the energy is worth more exported than the cheap grid import it would replace, so export it and buy the dip from grid.

So a SOLAR_EXPORT period showing discharge_rate=0 is not a bug — it means prices were inverted that period. And discharge_rate=100 on SOLAR_EXPORT does not mean the battery is being drained: load_first only discharges to an actual house deficit, and at 15-minute resolution a SOLAR_EXPORT period is net surplus (deficit 0), so planned vs realized economics are unchanged. The gate only affects sub-15-minute hardware behaviour.

LOAD_SUPPORT does NOT use this gate (#393 — reverted #384/#385). #384 briefly extended this gate to LOAD_SUPPORT (discharge_rate = max(planned_rate, gate_result), raising but never lowering the plan-scaled ceiling), reasoning that load_first's physical self-limiting to the real house deficit made an open ceiling safe. Two problems surfaced:

  • #385's own validation against the reporting user's real captured data found the gate does not open during the sustained overnight near-tie regime it was built to fix — shadow_price sits within a cent or two of buy_price for the whole stretch there (that near-tie is close to the defining condition for choosing LOAD_SUPPORT at all), so the strict inequality rarely trips in exactly the case that motivated the change.
  • Replaying a full day of real captured data from a second, independent report showed the same gate condition evaluating true for the large majority of LOAD_SUPPORT periods (51/67, ~76%) — not the rare "reserve genuinely not needed elsewhere" case the gate was designed for. In practice this meant a broad, mostly-untested override of the #147 reservation pacing (LOAD_SUPPORT deliberately reserves battery for a later, pricier period rather than dumping at full rate).

LOAD_SUPPORT is back to its plan-scaled cap unconditionally, matching pre-#384/v9.9.0b23 behavior — no shadow-price gate at all. The original overnight-leak problem #381/#384 described (small real grid imports, 0.1–0.2 kWh/night, while SOE has ample headroom above the floor) remains open and tracked in #393, to be revisited with a mechanism actually validated against real captured data across representative regimes (not just the motivating case) before it ships again. See core/bess/tests/unit/test_load_support_gate_regression_393.py, which replays real captured data (regression_2026_07_26_203726.json) reproducing the 76% figure and asserting LOAD_SUPPORT's discharge_rate never exceeds the plan-scaled baseline regardless of shadow_price.

The inverter AC output cap (solar clipping avoidance)

inverter_max_ac_power_kw (BatterySettings, default 0 = disabled) models a hybrid inverter whose total AC output (PV DC→AC conversion plus battery discharge) is capped — e.g. 5 kW on a Growatt MIN 5000TL-XH — while DC-coupled PV above the cap can still charge the battery directly, but only while the battery has room. With the cap set:

  • Clipped solar is worth zero in the DP: per period, solar not stored DC-side is deliverable to home/grid only up to cap × (1 − inverter_ac_power_margin) × dt; the excess is clipped_solar (reported per period on EnergyData and as clippedSolar in the API). A full battery during above-cap solar is therefore genuinely costly, which is what pushes the optimizer to reserve headroom for the midday peak.
  • Deferring absorption uses the SOLAR_EXPORT-below-max bypass (#313): normally IDLE passively absorbs surplus, so a reward change alone cannot defer charging. The existing bypass candidate (SoE held exactly unchanged, surplus exports up to the cap, the rest clips) is what expresses "export the surplus, keep the room" — with the cap set, its reward is cap-aware, so the DP chooses it ahead of the above-cap window. These periods classify as SOLAR_EXPORT with battery_action = 0 and a not-full battery, meaning "deliberately holding for later overflow".
  • Hardware mapping: SOLAR_EXPORT blocks passive charging (#313), stopping load_first from filling the battery from surplus solar. On a genuinely full battery this is a no-op. The mechanism differs by platform: register- based hardware (Growatt TOU/cloud/SPH) writes charge_rate=0 via the EMS register; VPP-style hardware has no such register — it instead selects grid_first (battery held flat) via a forced vpp_power=0 command with remote control kept enabled, instead of disabling remote control into self-use (#355, not yet real-hardware-validated — see docs/superpowers/specs/2026-07-20-vpp-passive-charge-block-design.md). The shadow-price discharge gate above is unchanged and orthogonal.
  • Discharge shares the cap: battery discharge is limited to the AC headroom the (possibly clipped) solar leaves (cap − min(solar, cap) per period), both in the DP's feasible actions and in the simulator.
  • The margin (default 0.05) is a model-side haircut on the cap compensating for hourly Solcast forecasts flattening sub-period peaks; it is never written to hardware.
  • Requires per-period charge-rate control (Growatt MIN). On platforms without it (SPH, SolaX native) the plan is cap-aware but deferred absorption is not hardware-enforceable.

Execution Layer: What Can Override the Schedule

The DP schedule is not the last word — several mechanisms outside the optimizer can change what the hardware actually does. Check these before concluding a mechanism is "missing" from the DP when observed behavior doesn't match the schedule:

  • Discharge inhibit sensor: an external binary_sensor (auto-detected by entity ID suffix _charging/_is_charging, e.g. EV charging status) can force discharge_rate to 0 regardless of what the schedule says, checked independently of the 15-min optimization cycle (core/bess/battery_system_manager.py:3089-3113, polled every minute) and applied at schedule-write time (core/bess/battery_system_manager.py:2578-2582). If a period's Observed behavior shows no discharge despite Intent: BATTERY_EXPORT or LOAD_SUPPORT, check for an active discharge-inhibit sensor before suspecting the DP or the intent-to-hardware mapping.
  • Temperature derating: charge power can be capped below the configured max on cold days via a weather-forecast-driven derating curve (core/bess/battery_system_manager.py:1917-1966, _get_temperature_derated_charge_limits). If the weather entity isn't configured, this silently returns no derating rather than failing — so its absence in one installation vs. presence in another is expected, not a bug.
  • charging_power_rate setting is cosmetic after startup (known limitation, not a documented mechanism): this settings-page value only seeds the initial charge-power target once, before the first control cycle. Every cycle after that, the actual hardware charge rate comes from INTENT_TO_CONTROL, which only ever emits 0% or 100% — it never reads this setting again (core/bess/battery_system_manager.py:2037-2064, adjust_charging_power). If a user reports "changing the charge power rate slider did nothing," this is why — it is a known bug, tracked in TODO.md, not a settings-propagation issue to re-diagnose from scratch.

Price Calculation

The optimizer works with buy and sell prices derived from spot prices:

buy_price  = (spot + markup) * VAT_multiplier + additional_costs
sell_price = spot + export_compensation

For Octopus Energy (UK), prices are already final — no markup/VAT applied.

For when a discharge is worthwhile, see The Governing Economic Law above — gross sell_price vs cycle_cost is not the test; marginal value vs the counterfactual is.

Energy Flow Decomposition

The system decomposes measured energy totals into detailed flows using energy conservation, but flows are clamped to measured grid totals (grid_imported/grid_exported) rather than derived by pure subtraction — pure subtraction can invent flows out of cross-sensor noise (fixed in PR #342). See core/bess/models.py (EnergyData._calculate_detailed_flows, ~lines 90-146) and core/bess/energy_flow_calculator.py (~lines 176-183) for the current formulas, e.g.:

solar_to_battery = max(0, solar_production - export_to_grid
                         - self_consumption + battery_discharged)
solar_to_battery = min(solar_to_battery, battery_charged, solar_production)

Home consumption gets solar first (free), then grid. Battery charges from solar first (free), then grid (paid) — but the exact split is reconciled against measured grid import/export, not assumed from production figures alone.

A second, related noise source lives one level up: even after #342's zero-aggregate cap, a battery_to_grid residual can still survive when its governing aggregate (battery_discharged) is itself nonzero — the residual is then indistinguishable from ordinary lifetime-counter quantization (documented 0.1 kWh resolution, sensor_collector.py:235) rather than a real export, and it corrupts infer_intent_from_flows's observed_intent (BATTERY_EXPORT requires an inverter mode change; a residual this small proves nothing about mode). Fixed in #350: _calculate_detailed_flows folds any battery_to_grid below the 0.1 kWh floor back into battery_to_home, but only when battery_to_home > 0 — i.e. only when the battery was already covering a genuine home deficit and the residual plausibly reflects under-reading on that same deficit. When battery_to_home == 0 (home's need already fully met by solar), any nonzero export — however small — has no other channel to have come from and is left as a real export (see the R==P Bellman-guardrail regression test in test_dp_no_guardrails.py, which requires exactly this for a genuine 0.05 kWh 100%-export discharge). Note the DP's own planning-time classifier, classify_strategic_intent in decision_intelligence.py, already used battery_to_grid > 0.1 kWh as its threshold — #350 brings the observational path's noise handling in line with that existing precedent, though the two classifiers remain otherwise distinct (planning vs. after-the-fact labeling).

Prediction Snapshots and Expected Savings

Every time the optimizer runs, a prediction snapshot is saved recording:

expected_savings = actual_savings + predicted_savings
  • Actual savings: Sum of savings for completed time slots (past).
  • Predicted savings: Sum of savings for future time slots (from the latest optimization schedule).

Expected savings should NOT naturally decrease as time passes. As the day progresses, predictions become actuals, but the total should stay roughly the same IF the system performs as predicted.

If expected savings DROP between snapshots, it means something changed:

  1. Tomorrow's prices became available — the optimizer now sees a longer horizon and may shift profitable discharge from today to tomorrow. Check: did the schedule's horizon expand? Do tomorrow's prices exist?

  2. Actual solar was lower than forecast — less free energy means more grid purchases. Check: compare Historical Data solar column vs what the schedule predicted for the same time slots.

  3. Actual consumption was higher than estimated — more demand than expected (e.g., EV charging). Check: compare Historical Data import column vs schedule predictions.

  4. Prices changed between runs — updated price data shifted the economics. Check: logs for price fetch events.

NEVER say savings "naturally decay" or "diminish over time." A drop is always caused by a specific, identifiable change.

Consumption Prediction Strategies

The optimizer needs a consumption forecast. Four strategies exist:

  • ha_statistics (recommended): Builds a 96-period time-of-day profile from the past 7 days of HA Recorder data, bucketed by hour-of-day. For each hour it drops only the single highest (and lowest, if ≥5 samples) of the 7 daily values before averaging. This discounts a one-off irregular spike (e.g. an unusual EV charging session on one day) but does not strip out a regular/nightly EV charging habit — if most of the 7 samples for an hour are elevated together, the average stays high and the forecast correctly bakes that load in. Higher during evening peaks, lower overnight.
  • influxdb_7d_avg: Same concept but queries InfluxDB instead of HA.
  • sensor: Reads a 48-hour rolling average sensor. Produces a flat prediction (same value all day).
  • fixed: A single fixed kWh/hour value. Does not adapt.

Savings Calculation

There are two savings metrics. The distinction matters when reporting numbers:

Total savings (shown on the dashboard Savings card):

total_savings = grid_only_cost - hourly_cost

This is the full benefit of having solar + battery compared to grid-only.

Battery-only savings (per-period hourly_savings in data tables):

hourly_savings = solar_only_cost - hourly_cost

This isolates the battery's contribution on top of what solar already saves.

Total savings = solar savings + battery savings. Summing per-period hourly_savings gives a lower number than the dashboard total because it excludes the solar benefit.

Positive savings = the system saved money. Negative savings = the battery action cost more than doing nothing (can happen during charging periods — the benefit comes later when discharging).

Cost baselines:

  • grid_only_cost: Cost if no solar or battery existed (all consumption from grid)
  • solar_only_cost: Cost with solar but no battery optimization
  • hourly_cost (aka optimized cost): Actual cost with full optimization

Evidence-Based Analysis

When analyzing system behavior:

  • Every claim must be backed by specific data — a row in the data tables, a log line, or a line of source code.
  • NEVER speculate. Do not use "likely", "probably", "suggests", "may have". State what happened with evidence, or say you don't have enough data.
  • Start from what the data shows, not from a theory.
  • Use tools (read_file, search_code) to verify claims against actual code.