Description
Hello,
in the Lan it work fine. But if I install it on a Computer make the port forwarding correct the hytera repeater wont connect.
on DMR+ and Brandmeister I can connect. maybe we need dynamic ports?
Logs:
INFO - 2023-08-12 10:48:42,239 - BridgeSettings - Hytera Repeater is expected to connect at 192.168.1.106 and ports [MASTER PORT: 50000] [DMR PORT: 50001] [RDAC PORT: 50002]
ERROR - 2023-08-12 10:48:59,245 - MMDVMProtocol - PARAM: homebrew.repeater_dmr_id CURRENT_VALUE: 0 MESSAGE: Value might have not been configured and was not obtained in
Hytera repeater configuration process (either P2P, RDAC or SNMP)
ERROR - 2023-08-12 10:48:59,245 - MMDVMProtocol - PARAM: homebrew.callsign CURRENT_VALUE: None MESSAGE: Value might have not been configured and was not obtained in Hyt
era repeater configuration process (either P2P, RDAC or SNMP)
INFO - 2023-08-12 10:48:59,245 - MMDVMProtocol - Sending Login Request
DEBUG - 2023-08-12 10:48:59,246 - HyteraP2PProtocol - RDAC Accept for 46.114.174.112.50428
INFO - 2023-08-12 10:48:59,247 - MMDVMProtocol - Not sending packet, waiting for Hytera repeater to connect first
DEBUG - 2023-08-12 10:48:59,248 - HyteraP2PProtocol - DMR Accept for 46.114.174.112.60789
DEBUG - 2023-08-12 10:48:59,251 - HyteraP2PProtocol - RDAC Accept for 46.114.174.112.50428
DEBUG - 2023-08-12 10:48:59,252 - HyteraP2PProtocol - DMR Accept for 46.114.174.112.60789
DEBUG - 2023-08-12 10:49:02,212 - HyteraP2PProtocol - RDAC Accept for 46.114.174.112.50428
You its other port 60789 and 50428.
maybe its possible to solve it